Flame-retardant, fire-resistant plastic insulated wire

Rated voltage U0/U is 450/750V, 300/500V and 300/300V. The maximum permissible operating temperature of the cable conductor is 70℃. The ambient temperature during cable laying should not be lower than 0℃.
View More +

Polyvinyl chloride insulated cables with rated voltage of 450/750V and below

This product is suitable for power devices, fixed wiring and flexible connecting electrical appliances with a rated voltage of 450/750V or less.
View More +

Plastic insulation (low smoke, halogen-free) wire

Rated voltage U0/U is 450/750V, 300/500V and 300/300V. The maximum permissible operating temperature of the cable conductor is 70℃. The ambient temperature during cable laying should not be lower than 0℃. Cable bending radius.
View More +

Rated voltage 0.6/1kV cross-linked polyethylene insulated variable frequency cable

Rated voltage U0/U is 0.6/1KV. The maximum allowable long-term operating temperature of the cable conductor is 90℃. During a short circuit (lasting no more than 5s), the maximum temperature of the cable conductor shall not exceed 250℃. The ambient temperature during cable laying should not be lower than 0℃. The bending radius of the cable should not be less than 15 times the outer diameter of the cable.
View More +

Rated voltage 0.6/1kV cross-linked polyethylene insulated variable frequency cable

Rated voltage U0/U is 0.6/1KV The maximum allowable long-term operating temperature of the cable conductor is 90℃ During short circuit (maximum duration not exceeding 5s), the maximum temperature of the cable conductor shall not exceed 250℃ The ambient temperature during cable laying shall not be lower than 0℃ The bending radius of the cable shall not be less than 15 times the outer diameter of the cable
View More +

Rated voltage 0.6/1kV extruded insulation low-smoke, halogen-free power cable

This product is suitable for fixed installation in distribution networks or industrial equipment with a rated voltage of 0.6/kV or less.
View More +

Rated voltage 0.6/1kV extruded insulated fire-resistant power cable

This product is suitable for fixed installation in power distribution networks or industrial equipment with fire resistance requirements rated at 1 kV and below.
View More +

0.6/1kV extruded insulated power cable

This product is suitable for fixed installation in distribution networks or industrial equipment with a rated voltage of 0.6/kV or less.
View More +

Rated voltage 0.6/1kV (Um=1.2kV) copper conductor plastic insulated (low smoke, halogen-free) prefabricated branch cable

This product is widely used in power distribution systems for residential buildings, office buildings, hotels, hospitals, shopping malls, and factories.
View More +

Rated voltage 0.6/1kV (Um=1.2kV) copper conductor plastic insulated (flame retardant, fire resistant) prefabricated branch cable

This product is widely used in power distribution systems for residential buildings, office buildings, hotels, hospitals, shopping malls, and factories.
View More +

Rated voltage 0.6/1kV (Um=1.2kV) copper core plastic insulated prefabricated branch cable

This product is widely used in power distribution systems for residential buildings, office buildings, hotels, hospitals, shopping malls, and factories.
View More +

Flame-retardant computer and instrument cables

The product is suitable for fixed installation in electronic computer systems, monitoring circuits, and automated control systems with rated voltage (U0/U) of 300/500V or less, used for signal transmission and instrument detection connections.
View More +

Computer and instrument cables

This product is suitable for fixed installation in electronic computer systems, monitoring circuits, and automated control systems with a rated voltage (U0/U) of 300/500V or less, used for signal transmission and instrument detection connections.
View More +

Overhead insulated cables with a rated voltage of 1KV or less

This product has a rated voltage of U of 1kV or less, and is used for overhead fixed laying and lead-in wires.
View More +

Rated voltage 10kV overhead insulated cable

This product has a rated voltage U of 10kV and is for overhead fixed installation. The soft copper core product is used for transformer grounding wires; when installing the cable, the distance between the cable and trees should be considered, and during cable operation, frequent contact between the cable and trees is permitted.
View More +