Rated voltage 0.6/1kV extruded insulated fire-resistant power cable
Belongs to category:
Detailed content
Product Standard
This product is manufactured according to GB/T12706-2008 "Power cables and accessories with rated voltage from 1kV to 35kV, Part 1: Cables with rated voltage 1kV and 3kV" and GB/T 19666-2005 "General technical conditions for flame-retardant and fire-resistant wires and cables". It can also be manufactured according to IEC standards recommended by the International Electrotechnical Commission, British BS standards, German DIN standards, American ICEA standards, and Japanese JIS standards according to user needs.
Scope of Application
This product is suitable for fixed installation in places with fire resistance requirements in distribution networks or industrial equipment with rated voltage of 1kV and below.
Usage Characteristics
Rated voltage U0/U is 0.6/1KV
 0.6/1kV cross-linked polyethylene insulated power cable 
 
The maximum allowable long-term operating temperature of the cable conductor is 90℃ 
 
During short circuit (maximum duration not exceeding 5s), the maximum temperature of the cable conductor does not exceed 250℃ 
 
The ambient temperature during cable laying should not be lower than 0℃ 
 
The bending radius of the cable is not less than 15 times the outer diameter of the cable 
 0.6/1kV polyvinyl chloride insulated power cable 
 
The maximum allowable long-term operating temperature of the cable conductor is 70℃ 
 
During short circuit (maximum duration not exceeding 5s), the maximum temperature of the cable conductor does not exceed 160℃ 
 
The ambient temperature during cable laying should not be lower than 0℃ 
 
The bending radius of the cable is not less than 15 times the outer diameter of the cable 
Cable Model and Name
 Model Name 
 
NH-YJV Copper core cross-linked polyethylene insulated polyvinyl chloride sheathed fire-resistant power cable 
 
ZAN-YJV Copper core cross-linked polyethylene insulated polyvinyl chloride sheathed flame-retardant Class A fire-resistant power cable 
 
ZBN-YJV Copper core cross-linked polyethylene insulated polyvinyl chloride sheathed flame-retardant Class B fire-resistant power cable 
 
ZCN-YJV Copper core cross-linked polyethylene insulated polyvinyl chloride sheathed flame-retardant Class C fire-resistant power cable 
 
NH-YJV22 
 
Copper core cross-linked polyethylene insulated steel tape armored polyvinyl chloride sheathed fire-resistant power cable 
 
ZAN-YJV22 
 
Copper core cross-linked polyethylene insulated steel tape armored polyvinyl chloride sheathed flame-retardant Class A fire-resistant power cable 
 
ZBN-YJV22 
 
Copper core cross-linked polyethylene insulated steel tape armored polyvinyl chloride sheathed flame-retardant Class B fire-resistant power cable 
 
ZCN-YJV22 
 
Copper core cross-linked polyethylene insulated steel tape armored polyvinyl chloride sheathed flame-retardant Class C fire-resistant power cable 
 
NH-VV Copper core polyvinyl chloride insulated polyvinyl chloride sheathed fire-resistant power cable 
 
ZAN-VV Copper core polyvinyl chloride insulated polyvinyl chloride sheathed flame-retardant Class A fire-resistant power cable 
 
ZBN-VV Copper core polyvinyl chloride insulated polyvinyl chloride sheathed flame-retardant Class B fire-resistant power cable 
 
ZCN-VV Copper core polyvinyl chloride insulated polyvinyl chloride sheathed flame-retardant Class C fire-resistant power cable 
 
NH-VV22 
 
Copper core polyvinyl chloride insulated steel tape armored polyvinyl chloride sheathed fire-resistant power cable 
 
ZAN-VV22 
 
Copper core polyvinyl chloride insulated steel tape armored polyvinyl chloride sheathed flame-retardant Class A fire-resistant power cable 
 
ZBN-VV22 
 
Copper core polyvinyl chloride insulated steel tape armored polyvinyl chloride sheathed flame-retardant Class B fire-resistant power cable 
 
ZCN-VV22 
 
Copper core polyvinyl chloride insulated steel tape armored polyvinyl chloride sheathed flame-retardant Class C fire-resistant power cable 
 
Note: Single-core armored cables are only used for DC systems. If used in AC systems, non-magnetic material armor or magnetic shielding measures should be adopted. 
Production Range
 Model Core Number Nominal Cross-section 
 
mm 2
 
NH-YJV、 ZAN-YJV ZBN-YJV、ZCN-YJV NH-VV、ZAN-VV 、ZBN-VV、ZCN-VV 1 1.5-630 
 
NH-YJV22、ZAN-YJV22 ZBN-YJV22、ZCN-YJV22 NH-VV22、ZAN-VV22 ZBN-VV22、ZCN-VV22 10-630 
 
NH-YJV、 ZAN-YJV、ZBN-YJV、ZCN-YJV NH-VV、ZAN-VV 、ZBN-VV、ZCN-VV 2、3、4、5 1.5-400 
 
NH-YJV22、ZAN-YJV22 ZBN-YJV22、ZCN-YJV22 NH-VV22、ZAN-VV22 ZBN-VV22、ZCN-VV22 4-400 
 
NH-YJV、 ZAN-YJV、ZBN-YJV、ZCN-YJV NH-VV、ZAN-VV 、ZBN-VV、ZCN-VV 3+1 
 
4+1 
 
3+2 1.5-400 
 
NH-YJV22、ZAN-YJV22 ZBN-YJV22、ZCN-YJV22 NH-VV22、ZAN-VV22 ZBN-VV22、ZCN-VV22 4-400 
Keywords: Rated voltage 0.6/1kV extruded insulated fire-resistant power cable
Next Page