  • 6kV~35kV铜芯、铝芯、交联聚乙烯绝缘电力电缆.jpg

6kV~35kV copper-core, aluminum-core, cross-linked polyethylene insulated power cable

• Rated voltage U0/U at power frequency is 3.6/6kV~26/35kV. YJV medium-voltage cable • Maximum permissible operating temperature of cable conductor: 90℃. • During short circuit (maximum duration not exceeding 5s), the maximum temperature of the cable conductor shall not exceed 250℃. • Ambient temperature during cable laying should not be lower than 0℃. • Cable bending radius: Not less than 15 times the outer diameter of the cable for three-core cables; not less than 20 times the outer diameter of the cable for single-core cables.

Detailed content

Product Standard

This product is manufactured according to GB/T12706-2008 "Power cables and accessories with extruded insulation for rated voltages from 1kV to 35kV Part 2 Cables with rated voltages of 6kV and 30kV Part 3 Cables with rated voltages of 35kV", and can also be manufactured according to IEC, British, German and American standards as required by the user.

 

Scope of Application

This product is suitable for fixed installation in distribution networks or industrial equipment with a rated voltage of 35kV or below.

 

Operating Characteristics

• Rated power frequency voltage U0/U is 3.6/6kV~26/35kV. YJV medium voltage cable

• The maximum allowable operating temperature of the cable conductor is 90℃.

• During a short circuit (maximum duration not exceeding 5s), the maximum temperature of the cable conductor does not exceed 250℃.

• The ambient temperature during cable laying should not be lower than 0℃.

• Cable bending radius: not less than 15 times the outer diameter for three-core cables; not less than 20 times the outer diameter for single-core cables.

 

Selection of Cable Rated Voltage

• The rated voltage of the cable should be suitable for the operating conditions of the cable system, expressed as U0/U (Um) kV.

U0-Rated power frequency voltage between conductor and ground or metal shield used in cable design;

U-Rated power frequency voltage between conductors used in cable design;

Um-The maximum value of the "maximum system voltage" that the equipment can withstand.

• The recommended U0 values for three-phase system cables are shown in the table below:

U kV Um kV U0* kV
A and B Class Systems C Class Systems
6 7.2 3.6 6
10 12 6 8.7
15 17.5 8.7 12
20 24 12 18
30 36 18 —
35 40.5 21 26
A Class System──In this type of system, when any phase conductor comes into contact with the ground or grounding conductor, it can be separated from the system within 1 minute.
B Class System──This type of system only includes the conditions of short-term operation of single-phase ground faults, and the ground fault time should not exceed 1 hour, but under any circumstances, the maximum is not more than 8 hours per year. The total duration of ground faults should not exceed 125 hours;
C Class System──Systems that do not belong to Class A or Class B.

 

Cable Model

Model Name

YJV Copper conductor cross-linked polyethylene insulated polyvinyl chloride sheathed power cable
YJLV Aluminum conductor cross-linked polyethylene insulated polyvinyl chloride sheathed power cable
YJY Copper conductor cross-linked polyethylene insulated polyethylene sheathed power cable
YJLY Aluminum conductor cross-linked polyethylene insulated polyethylene sheathed power cable
YJV22 Copper conductor cross-linked polyethylene insulated steel tape armored polyvinyl chloride sheathed power cable
YJLV22 Aluminum conductor cross-linked polyethylene insulated steel tape armored polyvinyl chloride sheathed power cable
YJV23 Copper conductor cross-linked polyethylene insulated steel tape armored polyethylene sheathed power cable
YJLV23 Aluminum conductor cross-linked polyethylene insulated steel tape armored polyethylene sheathed power cable

 

Production Range

Model Core Number
Nominal Cross-section mm 2
YJV 3.6/6KV
YJLV 3.6/6KV 1 25-630
YJY 3.6/6KV
YJLY 3.6/6KV 3 25-630
YJV22 3.6/6KV
YJLV22 3.6/6KV 1 25-630
YJV23 3.6/6KV
YJLV23 3.6/6KV 3 25-630
YJV 6/6KV(YJV 6/10KV)
YJLV 6/6KV(YJLV 6/10KV) 1 25-630
YJY 6/6KV(YJV 6/10KV)
YJLY 6/6KV(YJLV 6/10KV) 3 25-630
YJV22 6/6KV(YJV22 6/10KV)
YJLV22 6/6KV(YJV22 6/10KV) 1 25-630
YJV23 6/6KV(YJV23 6/10KV)
YJLV23 6/6KV(YJV23 6/10KV) 3 25-630
YJV 8.7/10KV(YJV 8.7/15KV)
YJLV 8.7/10KV(YJLV 8.7/15KV) 1 25-630
YJY 8.7/10KV(YJV 8.7/15KV)
YJLY 8.7/10KV(YJLV 8.7/15KV) 3 25-630
YJV22 8.7/10KV(YJV22 8.7/15KV)
YJLV22 8.7/10KV(YJV22 8.7/15KV) 1 25-630
YJV23 8.7/10KV(YJV23 8.7/15KV)
YJLV23 8.7/10KV(YJV23 8.7/15KV) 3 25-630
YJV 12/20KV
YJLV 12/20KV 1 35-630
YJY 12/20KV
YJLY 12/20KV 3 35-630
YJV22 12/20KV
YJLV22 12/20KV 1 35-630
YJV23 12/20KV
YJLV23 12/20KV 3 35-630
YJV 18/30KV
YJLV 18/30KV 1 50-630
YJY 18/30KV
YJLY 18/30KV 3 50-500
YJV22 18/30KV
YJLV22 18/30KV 1 50-630
YJV23 18/30KV
YJLV23 18/30KV 3 50-500
YJV 26/35KV
YJLV 26/35KV 1 50-630
YJY 26/35KV
YJLY 26/35KV 3 50-500
YJV22 26/35KV
YJLV22 26/35KV 1 35-630
YJV23 26/35KV
YJLV23 26/35KV 3 50-500
Note: Single-core armored cables are only for DC systems. If used in AC systems, a non-magnetic armor layer or magnetic shielding measures should be adopted.

Keywords: 6kV~35kV copper-core, aluminum-core, cross-linked polyethylene insulated power cable